CMS: Chip Measurement System
|
|
|
|
|
|
CMS Analyzers |
CMS Chips |
 |
 |
|
|
CMS:
Chip Measurement System
The CMS
combines substance specific measuring Chips with an
electronic based Analyzer for an easy to use
spot-measurement system. The 10 capillaries in each Chip are
filled with a reagent system based on Draeger's 60+ years of
colorimetric chemistry expertise. The analyzer combines a
revolutionary optical system for analyzing the color
reaction with a mass flow controller and pump system that
provides unbeatable reproducibility.
Fast
Response Times
The CMS
Analyzer requires no warm-up time. After taking a test, the
results can be reported as quickly as 20
seconds. Higher concentrations, which pose a greater hazard,
are reported faster than trace background levels. This
increases the safety of using the CMS system. TWA and action
levels are typically analyzed within 1-2 minutes.
After providing the measurement results, the CMS is
immediately ready for another test or another Chip for
further analysis of the environment.
Unequalled Accuracy
The
expertise of Draeger's worldwide experience in industrial
gas measurement has come to focus in the CMS. This is
combined with a photo-optical controller that measures the
speed of the chemical reaction, thus eliminating the human
objectivity. Unlike other systems that rely on the volume of
air, the CMS pulls the same mass of air through the
capillary every time. The mass flow controller automatically
compensates for changes in atmospheric pressure.
Accuracies of +/- 4 to 7% of measured value is achieved for
most gases.
CMS
has been validated by a nationally accredited third party
laboratory.
Chemical
Specific Chips
When you
need to know exactly what is there, CMS is the tool to
provide those answers. The chemistry is chosen to provide
the best results possible. The capillaries of several chips
have multiple levels (Yes, even in something that small!) to
help eliminate cross sensitivity or derive a specific
measurement of the targeted chemical.
The CMS
Chip
The Chip
consists of 10 measurement capillaries filled with
substance-specific reagent systems. The gas type, part
number and batch number are printed on the chip. A printed
barcode on the chip, read by the analyzer optics, contains
information about gas type, measuring range and measuring
time required for completing the measurement. Each chip is
calibrated during manufacturing and is valid for two years. |
|
|
|
|
 |
| |
|
|
 |
|
|
| |
|
|