CMS Analyzer with Remote System
|
Usually ships in 5-7 days, Call 866-905-9791 if need is urgent!
Item Number: 8317700
Manufacturer: Draeger
Manufacturer Part No: 8317700
|
|
|
CMS Analyzer with Factory Installed Remote Pump; Includes 3 meter extension hose with Adaptor and Float Probe
|
Part Number: 8317700
Includes: Analyzer, 4 each AA Alkaline Batteries & 3mm Allen Wrench3 meter extension hose and float probe |
Ever since 1937 when Draeger introduced their first detector tube, they have been the world’s leader in analysis of gases and vapors in the industrial workplace. Over the years, they have developed more detection devices for more application than anyone else! Draeger’s leading edge technology has kept them on the forefront of Colorimetric Detector Tubes and portable gas detection instrumentation. The CMS further advances Draeger’s capabilities in industrial gas measurement for health, safety and process control. |
| |
| The CMS combines substance specific measuring Chips with an electronic based Analyzer for an easy to use spot-measurement system. The 10 capillaries in each Chip are filled with a reagent system based on Draeger's 60+ years of colorimetric chemistry expertise. The analyzer combines a revolutionary optical system for analyzing the color reaction with a mass flow controller and pump system that provides unbeatable reproducibility. |
| The CMS Analyzer requires no warm-uptime. After taking a test, the results can be reported as quickly as 20 seconds. Higher concentrations, which pose a greater hazard, are reported faster than trace background levels. This increases the safety of using the CMS system. TWA and action levels are typically analyzed within 1-2 minutes. After providing the measurement results, the CMS is immediately ready for another test or another Chip for further analysis of the environment. |
| One stroke tubes are not always faster! Though many Draeger-Tubes® require more than one stroke, they often provide measurement results in less time. Not only do you get the benefit of a quicker analysis; the larger sample volume provides better statistical accuracy. |
| The expertise of Draeger's worldwide experience in industrial gas measurement has come to focus in the CMS. This is combined with a photo-optical controller that measures the speed of the chemical reaction, thus eliminating the human objectivity. Unlike other systems that rely on the volume of air, the CMS pulls the same mass of air through the capillary every time. The mass flow controller automatically compensates for changes in atmospheric pressure.
Accuracies of +/- 4 to 7% of measured value is achieved for most gases. CMS has been validated by a nationally accredited third party laboratory. |
| |
The CMS Chip consists of 10 measurement capillaries filled with substance-specific reagent systems. The Gas Type, Part Number and Batch Number are printed on the Chip. A printed barcode on the Chip, red by analyzer optics, contains information about the gas type, measuring range and measuring time required to complete the measurement. Each Chip is calibrated during manufacturing and is valid for two years. |
| |
| When you need to know exactly what is there, CMS is the tool to provide those answers. The chemistry is chosen to provide the best results possible. The capillaries of several chips have multiple layers (Yes, even in something that small!) to help reduce cross sensitivity to derive a specific measurement of the targeted chemical. |
| The CMS is literally as easy to operate as1-2-3. Making an analysis is as simple as turning the unit ''on'' (moving the slide to position 1), then following the plain language instructions on the display to load the Chip and move the slide selector to positions 2 and 3. Operating the CMS couldn't be easier because this is the exact same procedure for every Chip! Upon completion of the analysis, the CMS Analyzer shows the concentration in the display. Any misinterpretation of the results is eliminated by the unambiguous digital display of the concentration. |
| The CMS Analyzer does not require gas calibration! All calibration information is stored on the bar code of the CMS Chip and automatically downloaded to the analyzer when inserted. An electronic system self test is performed every time the Analyzer is switched ON, and a sampling system test is performed before each test. You are always assured that the CMS system is operating properly. Operating on alkaline batteries means that there are no worries about charging or battery memory. CMS is gas detection made simple. |
| The internal data recorder stores up to fifty measurements with the time/date, contaminant/concentration and the sequential number of the measurement in a series. Measurement location information (in alphabetical code) may be entered manually. The stored data can be recalled and displayed on demand. |
| |
| Size: |
4.1 x 8.5 x 2.5 inch (105 x 215 x 65 mm) |
| Weight: |
25.6 oz. (730 g) |
| Operational Temp: |
32-104°F (0-40°C) |
| Ingress Protection: |
IP-54, protected against dust and water |
| Data Capacity: |
Stores up to 50 measurements |
| Power Supply: |
4 x 1.5 Volt (AA) alkaline batteries |
| Battery Duration: |
450 minutes of analysis time (typically greater than 100 measurements) |
| Approvals: |
UL: Class I, Division 1, Groups A-D, T4
CSA: Class I, Division 1, Groups A-D, T4
MSHA: Permissible Gas Detector
ATEX: EEx ib IIC T4 |
|
|
| Downloads: |
Broduct Brochure/Data Sheets - Click Here
CMS Operator Guide - Click Here |
|
|
|
|
| |
|
|
 |
| |