| SCape® CBRN30 | Tested and Proven For Unparalleled
Protection factor testing was completed in accordance with NIOSH Laboratory Respiratory Protection Level (LRPL) test protocol. This test was conducted by the U.S. Army at the Edgewood Chemical Biological Center in Edgewood, Maryland.
Results of the testing demonstrate that extremely high levels of protection are provided by SCape® CBRN30. An average fit factor (FF) of 97,953 was achieved for the 60 test trials. 52 of the 60 trials had an FF of 100,000 or greater. The minimum FF measured was 66,143 — far exceeding the NIOSH FF requirement of 2,000 or greater.
No fit testing required. |
| | Approved by NIOSH as a 30-minute General Category Escape Mask under the Standard for Chemical, Biological, Radiological and Nuclear (CBRN) Air-Purifying Escape Respirators (September 30, 2003) |
| | Features | | Automatic Blower Actuation Fool-proof operation. Blower automatically starts when hood is removed from case. User only has to put on the hood to be protected. One Size Eliminates logistical issues stemming from multiple sizes.
No Nosecup or Mouthbit Eliminates sizing difficulties. Dramatically improves communication — even with telephones, cell phones and other communication devices Blower Indicator Light Allows users (including hearing-impaired individuals) to determine that the product is operating. Comfortable Neck Seal One size neck seal. Beards/glasses/long hair accommodated easily. Not possible with faceseal mask. Very comfortable. Clear Hood/Large Visor Allows user to perform a wide range of tasks including reading, driving, etc. Total facial recognition. | Quiet 64 LPM Blower Delivers reliable protection with minimal training. Eases physiological burden on user. Reduces claustrophobic feelings associated with other hoods. Aids breathing for those with respiratory issues (e.g. asthma). Exhaust Valve The integral exhaust valve regulates/ maintains positive pressure within the hood. Filter Canister Military grade canister provides protection against a range of military agents and NIOSH TRAs (filter data). HEPA filter provides biological/radiological/particulate protection. Sealed Case Five-year shelf life. Eliminates need to perform any operations (e.g. filter plug removal) after removing product from package. |
|
 |
|
 |
 |
| |
FILTER DATA | All tests are conducted at 25°C | (1) Test was stopped at 60 minutes | (2) “SMARTMAN” Test | Test Agent | Test Concentration | %RH | Breakthrough | NIOSH Required | Actual Service | | | | Concentration | Service Life (min) | Life (min) | Ammonia | 1250 ppm | 25 | 25 ppm | 30 | >35 | | | 80 | | 30 | >35 | Cyanogen Chloride | 150 ppm | 25 | 2 ppm | 30 | >70 | | | 80 | | 30 | >40 | Sulfur Dioxide | 750 ppm | 25 | 5 ppm | 30 | >35 | | | 80 | | 30 | >35 | Cyclohexane | 1300 ppm | 25 | 10 ppm | 30 | >65 | | | 80 | | 30 | >45 | Formaldehyde | 250 ppm | 25 | 10 ppm | 30 | >60(1) | | | 80 | | 30 | >60(1) | Hydrogen Sulfide | 550 ppm | 25 | 30 ppm | 30 | >60(1) | | | 80 | | 30 | >60(1) | Nitrogen Dioxide | 100 ppm | 25 | 1 ppm NO2 | 30 | >60(1) | | | 80 | | 30 | >60(1) | Phosgene | 125 ppm | 25 | 1.25 ppm | 30 | >60(1) | | | 80 | | 30 | >60(1) | Hydrogen Cyanide | 470 ppm | 25 | 10 ppm | 30 | >60(1) | | | 80 | | 30 | >60(1) | Phosphine | 150 ppm | 25 | 0.5 ppm | 30 | >60(1) | | | 80 | | 30 | >60(1) | HD(2) | 50 mg/m3 vapor | Breathing | 0.6 mg/m3 | 60 | >60(1)min | Mustard Agent | & 25 drops liquid | Pump |
ct ≤ 6.0 | | | | | 40 lpm |
mg-min/m3 | | | GB(2) | 210 mg/m3 | Breathing | 0.087 mg/m3 | 60 | >60(1)min | Sarin | | Pump 40 lmp | | | | DOP | 160 mg/m3 | 50% RH | 0.03% | LOAD TO | <0.005% | Dioctyl Phthalate | | 85 lpm | | 200 mg | | PANIC DEMAND | | | | |
|
|
|
|
|
| |
|
| |